✍️ Episode 2.4 Topic Notes

📌 SSD Longevity & Maintenance Technologies:

  • Wear Leveling: NAND flash memory cells degrade after a finite number of Program/Erase (P/E) cycles. The SSD controller's wear-leveling algorithm distributes writes evenly across all physical flash blocks to prevent premature cell failure.
  • The TRIM Command: Informs the SSD controller which data blocks are no longer considered in use by the OS filesystem (e.g., deleted files), allowing the drive to proactively erase and garbage-collect those blocks to maintain peak write performance.

📌 Key RAID Mathematical Principles:

  • RAID 0 (Performance): Data blocks are interleaved sequentially across all drives ($D_1 \rightarrow \text{Disk 1}$, $D_2 \rightarrow \text{Disk 2}$). Write and read speeds scale proportionally with $N$, but any single drive crash destroys all data permanently.
  • RAID 1 (Redundancy): Identical data is simultaneously written to both disks. If one fails, the survivor immediately services I/O without downtime.
  • RAID 5 (Parity Balance): Parity is computed via bitwise Exclusive-OR (XOR):
  • RAID 6 (Dual Fault Tolerance): Uses two independent parity syndromes (Reed-Solomon / XOR) across all drives, enabling the array to survive the catastrophic simultaneous failure of two hard drives.